Kami Distributor alat-alat lab, alat Laboratorium, laboratory equipments, Humidifier Ultrasonic, Pelembab Ruangan, laboratory supply, lab supply, pathology lab,microbiology lab equipment, test lab, kulkas pendingin, chemical lab, oil analysis lab, dna lab, chemistry lab,medical lab, science lab, lab test science, lab equipment, industrial lab, laboratory industry, lab industry makanan, minuman, obat-obatan/ farmasi siap melayani Surabaya, Jakarta, Malang, Bandung, Semarang dan kota kota di seluruh Indonesia

Spektrofotometer (Spectrophotometer) dengan panjang Gelombang 320~1100nm

Spektrofotometer Spectrophotometer Wavelength 320~1100nm
Spektrofotometer Spectrophotometer Wavelength 320~1100nm

Harga : Rp 23.765.000

Place of Origin: Beijing China (Mainland)
Brand Name: HY
Size: 53X41X21
Measurement Range: 320~1100nm
Wavelength Range: 320~1100nm
Weight: 20KG
Model Number: RSL0227G
Features:

1 Microprocessor control, 16×2 LCD display

2 Auto zero and auto 100%T adjustment provided

3 Calibration curve can be set up by either measuring or entering up to 10 standards or entering K and B factors directly via the keyboard

4 Parameters can be saved for later use.

5 Up to 10 calibration curves can be stored and edited for user’s convenience

6 Data can be printed on an optional desktop printer and can be downloaded to a PC through RS-232

7 PC control provided for more accurate and flexible measurement requirements (optional)

8 Auto-wavelength controls (optional)

Specifications:

Wavelength: 320~1100nm

Wavelength accuracy: ±2.0nm

Wavelength reproducibility: 1nm

Monochromator : Single-beam, C-T type, grating 1200L/mm

Photometric accuracy: ±0.5%T

Photometric reproducibility: 0.3%T

Stray light: ≤0.1%T ( Na NO2 at 340nm)

Spectral bandwidth: 2nm (1, 2, 4nm optional)

0%T stability

100%T stability: 0.001A/30min (at 500nm, after warming up)

Operation mode: T, A, C, E

Photometric range: -0.3~3A

Display : 16X2 LCD

Detector: Silicon Photodiode

Light source : Tungsten halogen lamp

Power Requirement : 220/110V±10%,50/60HZ

Power consumption: 100W

Dimensions: 530×410×210mm

Codes: chinahcricl

Leave a Reply

Fill in your details below or click an icon to log in:

WordPress.com Logo

You are commenting using your WordPress.com account. Log Out / Change )

Twitter picture

You are commenting using your Twitter account. Log Out / Change )

Facebook photo

You are commenting using your Facebook account. Log Out / Change )

Google+ photo

You are commenting using your Google+ account. Log Out / Change )

Connecting to %s

%d bloggers like this: